CATEGORIAS

Compact Substation (Pad Mounted Transformer) | Xinhong Electrical

Xinhong Electrical manufactures 10kV-35kV compact substations (pad mounted transformers), integrated box type substation for solar farm, mining, grid project, pure copper winding, ISO CE CB certified.
Oct 23rd,2026 9 Visualizações

Compact Substation

Compact substation, also widely known as box type substation or pad mounted transformer, is a fully assembled prefabricated power distribution unit. It integrates high-voltage switchgear, distribution transformer, low-voltage panel, protection and control components inside one weatherproof enclosure. It skips complicated on-site civil construction and wiring work, featuring fast installation, small footprint and flexible deployment. It is one of the most popular power solutions for photovoltaic plants, industrial zones, mining sites and urban power upgrading globally.

Xinhong Electrical, a China transformer manufacturer with 15 years of industry experience, supplies custom compact substations matched with oil immersed transformer or dry type transformer core, capacity range from 100kVA to 25MVA, 6kV ~ 35kV class. All units adopt pure copper winding as standard, comply with IEC standards and hold ISO, CE, CB certifications.

Key Advantages of Our Compact Substation

  • Fully pre-tested in factory: Assembled, wired and tested before delivery, greatly cut on-site labor and commissioning time
  • Space-saving design: Compact structure, much smaller footprint than traditional brick-built substation
  • Strong environmental adaptability: Waterproof, dustproof, anti-corrosion enclosure, suitable for outdoor harsh conditions
  • Flexible transformer option: Choose oil immersed transformer or dry type transformer according to fire safety requirements
  • Complete protection system: Overcurrent, short circuit, overload, earth fault protection, optional remote monitoring module
  • Low operation noise, easy inspection and maintenance
  • Modular design: Easy expansion for staged project construction

Main Application Scenarios

Our pad mounted compact substations are exported to Southeast Asia, Africa, Central Asia, Middle East markets for these projects:
✅ Solar PV power stations and wind farm booster stations
✅ Mining, quarry, cement and heavy industrial plants
✅ Urban community, commercial complex, logistics park power supply
✅ Rural electrification and grid reconstruction projects
✅ Water treatment station, irrigation and pumping projects
✅ Temporary construction power supply

Technical Specification Overview

  • Rated voltage level: 6kV, 10kV, 20kV, 35kV
  • Rated capacity: 100kVA ~ 25MVA
  • Internal transformer: Oil immersed transformer (ONAN/ONAF) or Dry type transformer
  • HV side: RMU / load break switch, fuse protection
  • LV side: Distribution panel, outgoing circuits, metering module
  • Enclosure material: Galvanized steel / stainless steel, anti-rust coating
  • Protection class: IP33 / IP54 optional
  • Standard: IEC 62271, IEC 60076
  • Certification: ISO 9001, CE, CB
  • Connection group: Dyn11 as standard

Compact Substation Types We Supply

  1. European style compact substation Classic cabinet layout, separate compartments for high voltage, transformer and low voltage. Good ventilation, convenient maintenance, widely used for solar and industrial projects.
  2. American style pad mounted transformer Integrated tank structure, compact size, fewer external components, good sealing performance, popular for outdoor urban distribution.

We can design enclosure layout, color and internal configuration according to your local grid specification.

Standard Configuration & Optional Add-ons

✅ Standard

  • High voltage ring main unit (RMU)
  • Distribution transformer (pure copper winding)
  • Low voltage distribution cabinet with circuit breakers
  • Metering cabinet (energy meter)
  • Ventilation, lighting, grounding system ✅ Optional
  • Remote SCADA monitoring system
  • Temperature and smoke alarm
  • Fire suppression device (for dry type version)
  • Anti-condensation heater
  • Surge protection device
  • Custom painting and logo printing

Compact Substation VS Traditional Outdoor Substation

Traditional substation needs foundation construction, separate equipment delivery and on-site assembly, which takes long construction period and higher total cost. Compact substation is a turnkey solution. You only need a simple foundation, place the box, connect incoming and outgoing cables, then it can be put into service. It is the best choice for projects with tight schedule and limited land area.

Frequently Asked Questions

What is the difference between European and American box substation?

European box substation adopts three independent compartments, better heat dissipation and easier maintenance. American pad mounted transformer is more compact, oil tank integrated design, lower cost for small and medium capacity.

Can you match dry type transformer inside the compact substation?

Yes. If the substation is installed near residential areas or places with strict fire prevention rules, dry type transformer configuration is available.

Can you make custom voltage and metering scheme for different countries?

Yes. We support custom HV/LV voltage, connection group, metering method and protection logic to meet local utility requirements.

What certificates can you provide for customs clearance?

We provide CE, CB, ISO certificates, type test reports, factory inspection documents, commercial invoice, packing list and CO certificate. We can also assist for COC and other local mandatory certifications.

What is your production lead time?

Standard European/American pad mounted substation: 15–25 working days. Large capacity, special monitoring or custom anti-corrosion version: 25–40 working days.

Why Choose Xinhong Electrical for Compact Substation

We operate a 27000㎡ factory in Jiangsu China, with full production lines for transformers and box substation assembly. Every compact substation will go through routine test, partial discharge test and whole set linkage test before shipment. Our engineering team supports schematic drawing review, parameter selection and project technical discussion. We have rich export experience and accept flexible payment terms such as LC and DAP for overseas clients. OEM & ODM service is available.

Request A Custom Quotation

Please send us your required capacity, high & low voltage, type (European / American), internal transformer type, protection and metering requirements. Our engineers will prepare datasheet and formal quotation quickly.