Introduction

Oil‑immersed transformers are one of the most widely used transformer types in power systems. They play an indispensable role in power generation, transmission, and distribution. With transformer oil as the main insulating medium and cooling agent, they offer excellent electrical performance, reliable operation, and long service life, making them core equipment in modern power grids.

As a professional enterprise focused on power equipment, Xinhong Electrical has long been committed to the R&D and manufacturing of oil‑immersed transformers and other power products, providing safe, reliable, and efficient power solutions to customers. This article comprehensively analyses the structural composition and performance characteristics of oil‑immersed transformers to help users gain an in‑depth understanding of this crucial power device.


1. Overall Structure of Oil‑Immersed Transformers

The main structure of an oil‑immersed transformer consists of five major modules: the active part, the tank, the cooling system, the protective devices, and the bushing assembly.

  • The active part is the core, comprising the core, windings, insulation, leads, and tap changer.

  • The tank houses the active part and the transformer oil.

  • The cooling system dissipates the heat generated during operation.

  • The protective devices ensure safe operation.

  • The bushing assembly connects the transformer to the external circuit.


2. Detailed Analysis of Core Components

2.1 Core – The Magnetic Circuit

The core is the main magnetic path of the transformer. Its function is to convert electrical energy from the primary circuit into magnetic energy, and then from magnetic energy into electrical energy in the secondary circuit. The core is typically stacked from cold‑rolled grain‑oriented silicon steel sheets with a silicon content of about 4.5%, a thickness of 0.35 or 0.5 mm, and coated with an insulating varnish. The core consists of core columns (where windings are placed) and yokes(which close the magnetic path).

Modern high‑performance oil‑immersed transformers increasingly adopt three‑dimensional wound core technology. The three core columns are arranged in an equilateral triangle, resulting in a gapless magnetic circuit, tighter winding, equal and shortest magnetic paths. This design significantly reduces no‑load losses and noise, improves three‑phase balance, and reduces third‑harmonic components.

Xinhong Electrical uses high‑grade, high‑permeability cold‑rolled silicon steel in its transformer cores, with a fully inclined, no‑hole structure that effectively lowers no‑load losses and operational noise, ensuring stable and efficient performance over long‑term operation.

2.2 Windings – The Electrical Circuit

Windings form the electrical circuit of the transformer. They are usually wound from insulated copper conductors or copper foil on a winding mandrel. The windings are mounted on the core columns and are divided into the primary winding (connected to the power source) and the secondary winding (connected to the load).

In terms of layout, the low‑voltage winding is generally placed on the inner layer (close to the core), while the high‑voltage winding is wound over it. For low‑voltage windings, except for small capacities that use copper wire, most are cylindrical and wound with copper foil. High‑voltage windings adopt a multi‑layer cylindrical design to achieve balanced ampere‑turn distribution, low leakage flux, high mechanical strength, and strong short‑circuit withstand capability.

Insulating cylinders made of high‑grade materials are inserted between the high‑ and low‑voltage windings, and between the windings and the core, ensuring reliable electrical insulation. Oil ducts are reserved between the windings to allow transformer oil to circulate and dissipate heat.

Xinhong Electrical uses high‑quality oxygen‑free copper for its windings, offering high conductivity, low heat generation, and low losses, thereby improving overall energy efficiency.

2.3 Transformer Oil – Dual Role of Insulation and Cooling

Transformer oil is the defining feature of oil‑immersed transformers. Composed mainly of naphthenes, paraffins, and aromatic hydrocarbons, it serves two critical functions:

  • Insulation: It provides excellent electrical insulation between windings, between windings and the core, and between windings and the tank, effectively preventing dielectric breakdown.

  • Cooling: As the oil heats up, it convects, carrying heat away from the core and windings to the tank walls, where it is dissipated to the surrounding environment.

Common grades are No.10, No.25, and No.45, with the number indicating the pour point temperature in °C. Xinhong Electrical strictly controls oil quality by employing vacuum oil filling and degassing processes to minimise moisture and ensure long‑term insulation stability.

2.4 Tank – The Enclosure

The tank is the outer shell of the oil‑immersed transformer. It is filled with transformer oil and houses the core and windings. The tank is typically welded from steel plates with good sealing and corrosion resistance.

Modern designs often use corrugated tanks where the corrugated fins act as expandable radiators. They accommodate oil volume changes due to temperature variations through their own elasticity, eliminating the need for a separate conservator. This design reduces overall height and effectively prevents ingress of oxygen and moisture, slowing insulation degradation.

2.5 Conservator (Oil Reservoir)

The conservator is mounted on the tank cover and has a volume of about 10% of the tank. It stores and replenishes oil as the oil expands or contracts with temperature changes, ensuring that the core and windings remain immersed. It also reduces the oil‑air contact area, slowing oil oxidation.

A level gauge on the side of the conservator shows the oil level at different temperatures, helping maintenance personnel check oil quantity. A breather (dehydrating breather) is installed on the conservator to allow the upper space to communicate with the atmosphere, preventing tank deformation.

2.6 Bushings (Insulating Terminals)

Bushings are the main insulation components protruding from the tank. They are mostly made of porcelain and serve to bring the leads of the high‑ and low‑voltage windings out of the tank, providing insulation to ground (tank and core) and securing the leads for external connections. High‑voltage bushings are taller and more robust, while low‑voltage ones are shorter.

2.7 Cooling System

Oil‑immersed transformers generally employ one of the following cooling methods:

  • Oil‑natural air‑natural (ONAN): Cooling relies on natural oil convection and natural air circulation around the tank; suitable for small to medium capacities.

  • Oil‑natural air‑forced (ONAF): Fans are added to force air over the radiator surfaces, enhancing heat dissipation.

  • Oil‑forced air‑forced (OFAF): Pumps circulate hot oil through external coolers before returning it to the tank; used for large‑capacity transformers.

The radiator is the key component of the cooling system. Xinhong Electrical products feature optimally designed radiators with high heat‑exchange efficiency, effectively controlling temperature rise and extending service life.

2.8 Protective Devices

Several protective devices are incorporated to ensure safe operation:

  • Gas relay (Buchholz relay): Detects gas generated by internal faults and oil flow velocity. A light gas alarm signals, while a heavy gas trip initiates circuit breaker operation.

  • Pressure relief valve (explosion vent): Releases excess pressure automatically when internal pressure rises abnormally, preventing tank rupture.

  • Dehydrating breather (silica gel breather): Filters moisture and impurities from the air entering the conservator.

  • Thermometer: Monitors top oil temperature in real time to prevent overheating and insulation aging.

  • Tap changer: Adjusts the voltage ratio, available in off‑circuit (de‑energised) and on‑load (under load) types.


3. Key Performance Characteristics of Oil‑Immersed Transformers

Based on the above structural analysis, oil‑immersed transformers offer the following outstanding features:

  1. Excellent heat dissipation: Transformer oil has a high specific heat capacity, efficiently absorbing and transferring heat from the core and windings. Multiple cooling options suit various capacities and applications.

  2. Reliable insulation: The oil‑paper composite insulation system provides high dielectric strength for high‑voltage operation. The oil also excludes oxygen and moisture, slowing insulation aging.

  3. Low noise: The silicon steel laminations are immersed in oil, which penetrates the inter‑lamina gaps and dampens vibration, resulting in reduced operational noise.

  4. High mechanical strength and short‑circuit withstand capability: Robust winding structures and clamping ensure resilience against shipping vibration and short‑circuit forces.

  5. Low maintenance: Fully sealed designs effectively prevent oil degradation, eliminating the need for oil replacement during normal service life, thus lowering maintenance costs.

  6. Strong adaptability: Suitable for indoor, outdoor, high‑altitude, polluted, and coastal environments.

Xinhong Electrical manufactures oil‑immersed transformers in strict compliance with national standards such as GB/T 6451‑2023 Technical Parameters and Requirements for Oil‑Immersed Power Transformers and GB20052‑2024 Minimum Allowable Values of Energy Efficiency and Energy Efficiency Grades for Power Transformers. Our products achieve leading energy efficiency grades with low losses, low noise, and high reliability.


4. Comparison with Dry‑Type Transformers

The fundamental difference between oil‑immersed and dry‑type transformers lies in the use of transformer oil as the insulating and cooling medium. Oil‑immersed transformers have a sealed tank filled with oil, with windings immersed in oil and not visible from the outside. Dry‑type transformers typically use resin insulation and do not require an oil tank; the core and windings are visible.

In application, oil‑immersed transformers are more cost‑effective for large capacities and high voltages, while dry‑type transformers are preferred for indoor installations with stringent fire safety requirements and limited space.


5. Application Scenarios

Oil‑immersed transformers are widely used in:

  • Power plants and substations – as core equipment for voltage transformation and power transmission

  • Industrial and mining enterprises – providing stable power for production processes

  • Urban and rural distribution networks – stepping down high voltage to low voltage for end‑users

  • Renewable energy – step‑up transformers for solar PV and wind farms

  • Rail transit – power supply for railways and subways


Conclusion

Oil‑immersed transformers occupy an irreplaceable position in power systems due to their rational structure, stable performance, excellent heat dissipation, reliable insulation, and convenient maintenance. With continued advances in new materials and processes, their energy efficiency, reliability, and intelligence will further improve.

Xinhong Electrical will continue to deepen its expertise in power equipment, driven by technological innovation and quality excellence, to provide customers with high‑performance, high‑reliability oil‑immersed transformers and comprehensive technical support. For more product information or technical consultation, please feel free to contact us.